CubeSmart Self Storage Preliminary Site Plan
Description
Five single-story storage buildings (~69,000 sq ft) with one gated entrance. Tabled a month to sort out fire department concerns (hydrants, sprinklers, second entrance), written Public Works comments, weekend trip data, and Old Philadelphia Road improvements.
Impact summary
Adds self-storage capacity near Old Philadelphia Road and Route 715, with modest traffic (about six morning peak trips) that doesn't trigger a full traffic study, plus new city-owned water metering and a stormwater easement.
Applicant
- Name
- Real Estate Pursuits LC (The Peterson Companies)
- Address
- 727 Old Philadelphia Road, Aberdeen, MDSee this on the map
At a glance
- Hearings
- 2
- Public comments
- 0
- Total mentions
- 2
Last vote · Planning Commission
Discussed at 2 meetings in the last 60 days; most recently Nov 18, 2026.
Meeting timeline (2)
Planning Commission - Nov 18, 2026
Five single-story self-storage buildings (roughly 68,300 sq ft) on a 4.82-acre lot created by splitting the existing 42-acre industrial parcel. The commission approved the revised subdivision plat and the preliminary site plan, with conditions still to be met before it goes to the City Council.
Planning Commission - Oct 14, 2026
Five single-story storage buildings (~69,000 sq ft) with one gated entrance. Tabled a month to sort out fire department concerns (hydrants, sprinklers, second entrance), written Public Works comments, weekend trip data, and Old Philadelphia Road improvements.
Related issues (2)
Proposed self-storage facility on Old Philadelphia Road
The proposed storage facility sits across from the city's well field, in the recharge area for Aberdeen's drinking water wells. Commissioners are requiring an MOU with the developer covering prohibited materials like fuel and oil, since CubeSmart's lease rules (drained gas tanks, drip trays) depend on customer compliance and store manager enforcement.
Fire Safety of Non-Sprinklered Storage Buildings
The Aberdeen Fire Department vetted the plans in person this time. The outer storage buildings won't be sprinklered but must have three-hour firewalls every 2,500 square feet per code, an additional hydrant is required between Buildings A and B, and hydrant threads must match Harford County standards with ongoing maintenance.